Why knob-and-tube needs replacing
Knob-and-tube was the standard way to wire a Toronto house until about the 1940s, and plenty of it is still in service in the east end. It was not badly made for its time, but it is now 80 to 100 years old. The rubber and cloth insulation turns brittle, there is no ground conductor, and decades of later work often splice newer wire into it in ways it was never meant to handle. It was also designed to shed heat into open air, so where it has been buried in attic or wall insulation it can run hot.
Many insurers will not cover a house with live knob-and-tube, or will only do so for a short window while it is replaced. That is usually what prompts the call.
How we rewire with minimal damage
Most rewiring in older houses can be done by fishing new cable through existing wall and ceiling cavities instead of opening whole walls. We work from the basement and attic where possible and make small, planned openings where a run cannot be fished. Plaster walls in Beach and Danforth houses need care, and we place openings so they are quick to patch.
Work usually goes room by room or circuit by circuit, so most families stay in the house throughout. As each new circuit is connected, the old knob-and-tube run it replaces is disconnected at the panel, not left live in the wall.
Starting with an inspection
Before anyone prices a full rewire, it is worth knowing what is actually there. Some houses have one or two knob-and-tube circuits left; others have it throughout. We trace what is live, what has already been replaced and what is connected to what, then give you a clear picture of the scope. The rewire is often paired with a panel upgrade, since houses with knob-and-tube frequently still have 60 or 100 amp service. The work needs an ESA permit and inspection, and that paperwork is what your insurer will want to see afterwards.
How a knob-and-tube replacement goes
- Inspection. We trace the existing wiring and confirm how much knob-and-tube is still live.
- Scope and plan. A room-by-room plan showing which circuits get replaced, where openings will be, and whether the panel needs work too.
- Rewire in stages. New grounded circuits fished in and connected, old runs disconnected as we go. Most houses stay livable throughout.
- Inspection and records. Final ESA inspection, and documentation you can pass on to your insurer.